Description
Who Is the SL280 Sauna Red Light Panel Designed For?
SL280 is designed for sauna manufacturers, wellness equipment brands, spa distributors, hotel wellness projects, and private-label red light therapy companies requiring a heat- and moisture-resistant panel platform.
- Sauna manufacturers adding light therapy to cabin designs
- Wellness and spa distributors serving high-humidity installations
- Hotel and commercial wellness projects specifying durable, moisture-resistant equipment
- Red light therapy brands developing products for sauna and high-humidity applications
What Makes SL280 Different from a Standard Red Light Panel?
SL280 combines an IP65-rated enclosure, fanless aluminum heat dissipation, and high-temperature component selection to support indoor sauna and high-humidity wellness installations.
| Dimension | Typical Indoor LED Panel | SL280 |
|---|---|---|
| Enclosure | IP20 (no water protection) | IP65 — dust-tight and protected against water jets |
| Housing Material | Cold-rolled steel + aluminum trim | AL6063A extruded aluminum |
| Cooling | Active fan (noise, dust, humidity path) | Fanless passive cooling (low-noise, fewer enclosure openings) |
| Rated Environment | Usually intended for dry, temperature-controlled indoor use | Designed for specified high-temperature and high-humidity indoor environments |
| Thickness | Standard | 63 mm |
The Engineering Chain
This chain supports the product’s rated operation in high-temperature environments, subject to the specified installation and operating limits.
IP65: What It Means — and What It Doesn’t
- IP65 = dust-tight (6) + protected against water jets (5). SL280 is designed for specified high-humidity indoor environments, including compatible sauna and wellness installations, subject to the installation instructions, local electrical requirements, and the stated IP65 limitations.
- IP65 ≠ submersible. SL280 is not designed for immersion (IP67/IP68). This distinction helps brands communicate the product’s installation and usage limits clearly.
80°C Operating Temperature: What It Means — and What It Doesn’t
- 80°C = maximum rated ambient temperature. SL280 is rated for operation in ambient temperatures up to 80°C when installed and operated in accordance with the specified installation limits.
- 80°C ≠ the panel’s own surface temperature, or a fire-safety rating. The figure describes the environment, not the device. The 80°C rating applies to the panel under the specified test and installation conditions.
What Test Evidence Is Available for SL280?
| Evidence | Buyer Value | Status |
|---|---|---|
| IP65 Test Report | Confirms enclosure protection level | Available to qualified B2B buyers |
| Spectral Test Data | Confirms wavelength peaks | Available |
| Irradiance Test Data | Confirms output by mode and distance | Available |
| High-Temperature Operating Test | Confirms rated ambient operating conditions | Available upon request for qualified projects |
| Thermal Imaging / Temperature Test | Shows housing and component temperature behavior | Available upon request for qualified projects |
| CE / FCC / RoHS Documentation | Supports market and compliance evaluation | Available for applicable SL280 configuration |
What Wavelengths Does the SL280 Use?
SL280 combines two red-light wavelengths and four near-infrared wavelengths to give brands a broader wavelength configuration within one sauna-ready panel.
| Wavelength | Light Band | LED Count | Configuration Role |
|---|---|---|---|
| 630 nm | Red | 70 | Red-light channel |
| 660 nm | Red | 70 | Red-light channel |
| 810 nm | Near-Infrared | 30 | NIR channel |
| 830 nm | Near-Infrared | 34 | NIR channel |
| 850 nm | Near-Infrared | 70 | NIR channel |
| 1060 nm | Near-Infrared | 6 | Extended NIR wavelength option |
1060nm as a Specification Differentiator
Based on Wakelife’s review of selected sauna-oriented panel configurations available as of 2026, many models use wavelengths up to 850 nm or 880 nm. SL280 extends the installed wavelength set to 1060 nm, providing an additional specification-level differentiator for OEM brands.
Competitive configurations may change, so buyers should compare current model specifications.
How Is the SL280 Controlled?
Light Modes
| Mode | Active Wavelengths |
|---|---|
| M1 — All-Wavelength Mode | 630 / 660 / 810 / 830 / 850 / 1060 nm |
| M2 — Red-Light Mode | 630 / 660 nm |
| M3 — Near-Infrared Mode | 810 / 830 / 850 / 1060 nm |
Control Functions
| Function | Specification |
|---|---|
| Brightness | 10 levels: 10%–100% |
| Timer | Default setting: 10 minutes; maximum setting: 30 minutes |
| Continuous Output | Flicker-free |
| Pulse Mode | 10 Hz selectable pulse |
| Remote Control | Included |
| Bluetooth | Optional; available by OEM configuration |
What Is the SL280 Irradiance at Different Distances?
| Distance | Irradiance |
|---|---|
| 3 in (7.6 cm) | 100 mW/cm² |
| 6 in (15.2 cm) | 80 mW/cm² |
| 9 in (22.9 cm) | 70 mW/cm² |
| 12 in (30.5 cm) | 60 mW/cm² |
Reference irradiance values were recorded with all wavelengths active and brightness set to 100%. Full measurement conditions, instrument information, and test methodology are provided in the irradiance test documentation. Values are reference measurements and may vary with meter spectral response, test position, operating temperature, and production tolerance. The 3-inch measurement is a technical reference point, not a recommended usage distance.
Product Specifications
| Parameter | Specification |
|---|---|
| Model | Wakelife SL280 (Sunna Light series) |
| Input Voltage | AC 100–240V~, 50/60Hz |
| Rated Power | 240W |
| LED Count | 280 pcs |
| LED Type | SMD 5050 — Single Chip |
| Wavelengths | 630 / 660 / 810 / 830 / 850 / 1060 nm |
| Wavelength Ratio | 630:660:810:830:850:1060 = 70:70:30:34:70:6 |
| Beam Angle | 60° |
| Housing Material | AL6063A extruded aluminum |
| Ingress Protection Rating | IP65 — dust-tight and protected against water jets |
| Rated Ambient Temperature | Up to 80°C |
| Cooling | Fanless passive cooling (full aluminum body heat sink) |
| Brightness | 10 levels: 10%–100% |
| Timer | Default setting: 10 minutes; maximum setting: 30 minutes |
| Continuous Output | Flicker-free |
| Pulse Mode | 10 Hz |
| Remote Control | Included |
| Bluetooth | Optional; available by OEM configuration |
| Product Dimensions | 1013 × 276.2 × 63 mm (39.88 × 10.87 × 2.48 in) |
| Net Weight | 9.70 kg |
| Warranty | 5 Years |
| Carton Quantity | 1 pc |
Standard Accessories
Every SL280 ships with a complete installation kit:
| Accessory | Qty |
|---|---|
| Protective Eyewear | 1 |
| Power Cord | 1 |
| Door Hanger | 1 |
| Hanging Cable | 1 |
| Adjustable Pulley System | 1 |
| User Manual | 1 |
| Remote Controller | 1 |
| Cable Protection Sleeve | 1 |
OEM / ODM Customization
SL280 is built on a flexible manufacturing platform. Wakelife supports brand customization for sauna equipment companies, wellness product distributors, and red light therapy brands.
Private Label
- Logo — product, label, manual, and packaging
- Manual and packaging branding
MOQ: from 50 units
Configuration Customization
- Housing color
- Wavelength ratio and LED distribution
- Control interface
- Accessories
- Plug and cable configuration
MOQ: subject to project scope
ODM Development
- Structural modification
- Control logic and firmware
- Installation integration
- Market-specific compliance preparation
MOQ: subject to project scope
How SL280 Compares to ESPLUS Series Panels
Wakelife manufactures both the ESPLUS series (standard red light panels for dry environments) and the SL280 (sauna-grade panel). Choosing between them depends on your distribution channels:
| If your customers are… | Choose |
|---|---|
| Home users, clinics, fitness centers — dry, temperature-controlled environments | ESPLUS series |
| Sauna distributors, bathroom fixture wholesalers, spa high-humidity areas, hotel wellness projects | SL280 |
| Both — full market coverage | Carry both lines |
SL280 is a complementary product line, not a replacement for ESPLUS.
Quality & Compliance
Product-Level Documents
- CE Conformity Documentation
- FCC Test Documentation
- RoHS Test Documentation
- IP65 Test Report
- Design Patent
Factory Quality Credentials
| Credential | Scope |
|---|---|
| ISO 13485 | Medical device quality management system |
| MDSAP | Medical Device Single Audit Program |
Certification scope, model coverage, and market applicability should be verified for each final OEM configuration. Buyers should confirm local regulatory requirements before marketing or distributing the product in their target market.
Frequently Asked Questions
Can a red light panel be used in a sauna room?
Only if the panel is designed for hot and humid conditions. A standard indoor panel should not be assumed suitable for sauna use unless its IP rating, ambient-temperature rating, electrical construction, and installation conditions have been specifically verified. SL280 is built for sauna environments with IP65 protection, fanless passive cooling, and an 80°C rated ambient temperature.
What does IP65 mean for a sauna panel?
IP65 means the enclosure is dust-tight and protected against water jets. It supports use in specified high-humidity indoor environments when installed according to the product instructions and applicable electrical requirements. It is not designed for submersion.
What is the rated operating temperature of the SL280?
Up to 80°C ambient temperature. This rating describes the environment the device is designed to operate in, made possible by the fanless AL6063A aluminum chassis and passive cooling architecture.
How does the fanless cooling system work?
The full chassis is built from AL6063A extruded aluminum, which conducts heat away from the LEDs and dissipates it across the entire body — acting as a passive heat sink. Removing fan intake openings reduces noise, dust accumulation, and a major potential path for moisture ingress. The aluminum housing dissipates heat through passive conduction and surface cooling.
What can be customized for OEM/ODM?
Three tiers: Private Label (logo, manual, and packaging — MOQ 50 units), Configuration Customization (housing color, wavelength ratio, interface, accessories), and ODM Development (structural modification, control logic and firmware, installation integration, and market-specific compliance preparation). MOQ for customization depends on project scope.
What is the MOQ and lead time?
Private-label MOQ starts at 50 units. Sampling: 5–15 days. Mass production: 25–45 days. Custom configuration and ODM timelines depend on project scope.





